Use this procedure to resolve the following problem: Required cache data cannot be located for one or more disk units (SRC xxxx9050).
In order to interpret the hexadecimal information to get device addresses, see More information from hexadecimal reports . The Device Errors Detected field indicates the total number of disk units that are affected. The Device Errors Logged field indicates the number of disk units for which detailed information is provided. Under the Device heading, the unit address, type, serial number, and worldwide ID are provided for up to three disk units. Additionally, the adapter type, serial number, and worldwide ID for each of these disk units indicates the adapter to which the disk was last attached when it was operational.
After the cache data is written to the disk units and the system is powered off normally, the adapter or disk units can be moved to another location. This ends the procedure
Reclaim adapter cache storage. See Reclaiming IOP cache storage ..