Use this procedure to resolve the following problem: Multiple adapters not capable of similar functions or controlling same set of devices (SRC xxxx9074)
Perform the following:
In order to interpret the hexadecimal information to get device addresses. See More information from hexadecimal reports . The Problem description field indicates the type of problem. The type, serial number, and Worldwide ID of the connected adapter is also available.
| Problem description | Full description | Action | Adapter on which to perform the action |
|---|---|---|---|
| Secondary does not support RAID level being used by primary. | Secondary adapter detected that the primary has a RAID array with a RAID level that the secondary does not support. | Customer needs to upgrade the type of secondary adapter or change the RAID level of the array on the primary to a level that is supported by the secondary. | Physically change the type of adapter that logged the error. Change RAID level on primary adapter (remote adapter indicated in the error log). |
| Secondary does not support disk unit function being used by primary. | Secondary adapter detected a device function that it does not support. | Customer might need to upgrade the adapter code or upgrade the type of secondary adapter. | Adapter that logged the error. |
| Secondary is unable to find devices found by the primary. | Secondary adapter cannot discover all the devices that the primary has. | Verify the connections to the devices from the adapter
logging the error. View the disk units under each adapter using HSM to determine the SAS port with the problem. |
Adapter that logged the error. |
| Secondary found devices not found by the primary. | Secondary adapter has discovered more devices than the primary. After this error is logged, an automatic failover will occur. | Verify the connections to the devices from the remote
adapter as indicated in the error log. View the disk units under each adapter using HSM to determine the SAS port with the problem. |
Remote adapter indicated in the error log. |
| Secondary port not connected to the same numbered port on primary. | SAS connections from the adapter to the devices are incorrect. Common disk expansion drawers must be connected to the same numbered SAS port on both adapters. | Verify connections and re-cable SAS connections as necessary. | Either adapter. |
| Primary lost contact with disk units accessible by secondary. | Link failure from primary adapter to devices. An automatic failover will occur. | Verify cable connections from the adapter which logged the error. Possible disk expansion drawer failure. | Adapter that logged the error. |
| Other | Not currently defined. | Contact your hardware service provider. |