Use this procedure to resolve the configuration error: Incomplete
multipath connection between enclosures and device detected (SRC xxxx4041).
The possible cause is a failed connection caused by a failing component
within the device enclosure, including the device itself.
Note: The adapter
is not a likely cause of this problem.
Considerations:
- Power off the system, partition, or card slot before connecting and disconnecting
cables or devices, as appropriate, to prevent hardware damage.
- Some systems have the disk enclosure or removable media enclosure integrated
in the system with no cables. For these configurations the SAS connections
are integrated onto the system boards and a failed connection can be the result
of a failed system board or integrated device enclosure.
- Some configurations involve a serial attached SCSI (SAS) adapter connecting
to internal SAS disk enclosures within a system using a cable card. Keep in
mind that when the procedure refers to a device enclosure, it could be referring
to the internal SAS disk slots or media slots. Also, when the procedure refers
to a cable, it could include a cable card.
- When using SAS adapters in a Dual Storage IOA configuration, ensure that
the actions taken in this procedure are against the primary adapter (that
is, not the secondary adapter).
Attention: Removing functioning disk units in a disk array
is not recommended without assistance from your service provider. If functioning
disk units are removed, a disk array might become unprotected or failed and
additional problems could be created.