FCIOA

The fibre channel I/O adapter is the failing item.

Replace the fibre channel I/O adapter using the I/O adapter location information in the Service Action Log if it is available. If the location is not available, find the address of the I/O adapter, see System reference code (SRC) address formats, or see "System reference code (SRC) address formats" in the service guide for the system unit. Use the address to find the location, see Locating FRUs, or see "Locating FRUs" in the service guide for the system unit. If an I/O Processor SRC sent you here, replace the fibre channel I/O adapter associated with the I/O processor that logged the SRC.

Use the following table to determine the part number for the field replaceable unit (FRU):

CCIN or FFC Type and model Part number Description Location code
2787 9406-MMA 80P6417 Fibre Channel IOA (for disk drive attachment only) Un-P1-Cx
280D 9406-MMA 03N5014 4 Gbps Fibre Channel (1 Port) adapter Un-P1-Cx
280E 9406-MMA 03N5016 PCI-X Fibre Channel disk controller Un-P1-Cx
5704 9406-MMA 80P6416 Fibre Channel IOA (for removable media attachment only) Un-P1-Cx
576B 9406-MMA 32N1294 4 Gbps Fibre Channel (2 Port) adapter Un-P1-Cx
5774 9406-MMA 10N7255 Gigabit PCI Express Dual Port Fibre Channel Adapter Un-P1-Cx
57FC 9406-MMA To determine the FRU part number, remove the adapter from the system. Fibre Channel IOA Un-P1-Cx