PGDPART
- Power off the server. For information about how to power off the server, see the service guide for the server on which you are working.
- Verify that the service processor card, if present, is connected and seated correctly. See TWRCARD.
- Verify that the power supplies are connected and seated properly. See PWRSPLY.
- Power on the server.
- Is there a reference code 1xxx 2600?
- No: Go to the next step.
- Yes: Exchange the following FRUs one at a time:
- SPCN card, service processor card, or system backplane (as appropriate for the server, see the following tables for FRUs for the server on which you are working):
- Power supplies
- Memory DIMMs
- Processor cards
- Backplane
Use the following tables to determine the part number for the field replaceable unit (FRU):
8203-E4A, 9407-M15, 9408-M25
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
8203-E4A, 9407-M15, 9408-M25 |
42R7898 |
System backplane |
Un-P1 |
| |
8203-E4A, 9407-M15, 9408-M25 |
44V4195 |
Power supplies, ac |
Un-Ex |
| 4520 |
8203-E4A, 9407-M15, 9408-M25 |
77P6497 |
512MB DDR2 memory card |
Un-P1-Cx |
| 4521 |
8203-E4A, 9407-M15, 9408-M25 |
77P6498 |
1GB DDR2 memory card |
Un-P1-Cx |
| 4522 |
8203-E4A, 9407-M15, 9408-M25 |
77P6499 |
2GB DDR2 memory card |
Un-P1-Cx |
| 4523 |
8203-E4A, 9407-M15, 9408-M25 |
77P6500 |
4GB DDR2 memory card |
Un-P1-Cx |
| 4524 |
8203-E4A, 9407-M15, 9408-M25 |
87H3621 |
8GB DDR2 memory card |
Un-P1-Cx |
| 2947 |
8203-E4A, 9407-M15, 9408-M25 |
77P7504 |
16GB DDR2 memory card |
Un-P1-Cx |
8204-E8A, 9409-M50
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
8204-E8A, 9409-M50 |
10N9369 |
System backplane |
Un-P1 |
| |
8204-E8A, 9409-M50 |
44V3559 |
Power supplies, ac |
Un-Ex |
| |
8204-E8A, 9409-M50 |
42R6607 |
Power supplies, dc |
Un-Ex |
| 4520 |
8204-E8A, 9409-M50 |
77P6497 |
512MB DDR2 memory card |
Un-P1-Cx-Cy |
| 4521 |
8204-E8A, 9409-M50 |
77P6498 |
1GB DDR2 memory card |
Un-P1-Cx-Cy |
| 4522 |
8204-E8A, 9409-M50 |
77P6499 |
2GB DDR2 memory card |
Un-P1-Cx-Cy |
| 4523 |
8204-E8A, 9409-M50 |
77P6500 |
4GB DDR2 memory card |
Un-P1-Cx-Cy |
| 4524 |
8204-E8A, 9409-M50 |
87H3621 |
8GB DDR2 memory card |
Un-P1-Cx-Cy |
| 2947 |
8204-E8A, 9409-M50 |
77P7504 |
16GB DDR2 memory card |
Un-P1-Cx-Cy |
| |
8204-E8A, 9409-M50 |
10N9377 |
4.2 GHz POWER6, 2 Core Processor Card |
Un-P1-Cx |
| |
8204-E8A, 9409-M50 |
10N9380 |
4.7 GHz POWER6, 2 Core Processor Card |
Un-P1-Cx |
9406-MMA, 9117-MMA
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
9406-MMA, 9117-MMA |
10N8752 |
Service processor card (the SPCN function is built into the service processor card for this system) |
Un-P1-C11 |
| |
9406-MMA, 9117-MMA |
42R8010 |
Power supplies |
Un-Ex |
| 319B |
9406-MMA, 9117-MMA |
15R7433 |
512MB DDR2 memory card |
Un-P2-Cx-Cy |
| 319C |
9406-MMA, 9117-MMA |
15R7436 |
1GB DDR2 memory card |
Un-P2-Cx-Cy |
| 319E |
9406-MMA, 9117-MMA |
15R7439 |
2GB DDR2 memory card |
Un-P2-Cx-Cy |
| 319D |
9406-MMA, 9117-MMA |
15R7445 |
4GB DDR2 memory card |
Un-P2-Cx-Cy |
| 319F |
9406-MMA, 9117-MMA |
15R7448 |
8GB DDR2 memory card |
Un-P2-Cx-Cy |
| |
9406-MMA, 9117-MMA |
10N9146 |
3.5 GHz POWER6, 2 Core Processor Card |
Un-P2-Cx |
| |
9406-MMA, 9117-MMA |
10N9144 |
4.2 GHz POWER6, 2 Core Processor Card |
Un-P2-Cx |
| |
9406-MMA, 9117-MMA |
10N9139 |
4.7 GHz POWER6, 2 Core Processor Card |
Un-P2-Cx |
| |
9406-MMA, 9117-MMA |
42R7352 |
I/O Backplane |
Un-P1 |
| |
9406-MMA, 9117-MMA |
10N8550 |
System processor backplane |
Un-P2 |
5790, 7311-D11
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
5790, 7311-D11 |
22R3958 |
Power supplies |
Un-Ex |
| |
5790, 7311-D11 |
80P6626 |
I/O drawer backplane |
Un-P1 |
0595, 5095, 7311-D20
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
0595, 5095, 7311-D20 |
39J2781 |
Power supplies |
Un-Ex |
| |
0595, 5095, 7311-D20 |
39J0515 |
I/O drawer backplane |
Un-P1 |
5796, 7314-G30
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
5796, 7314-G30 |
10N8867 |
SPCN Card |
Un-P1-C8 |
| |
5796, 7314-G30 |
42R4491 |
Power supplies |
Un-Ex |
| |
5796, 7314-G30 |
10N7677 |
I/O drawer backplane |
Un-P1 |
- Is there a reference code 1xxx 2602?
- No: Go to the next step.
- Yes: Exchange the following FRUs one at a time:
- Is there a reference code 2603?
- No: This ends the procedure.
- Yes: Exchange the following FRUs one at a time:
- Service processor card
- Power supplies
- Backplane
Use the following tables to determine the part number for the field replaceable unit (FRU):
8203-E4A, 9407-M15, 9408-M25
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
8203-E4A, 9407-M15, 9408-M25 |
42R7898 |
System backplane (the service processor is part of the sytem backplane for this server) |
Un-P1 |
| |
8203-E4A, 9407-M15, 9408-M25 |
44V4195 |
Power supplies, ac |
Un-Ex |
8204-E8A, 9409-M50
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
8204-E8A, 9409-M50 |
10N9369 |
System backplane (the service processor is part of the sytem backplane for this server) |
Un-P1 |
| |
8204-E8A, 9409-M50 |
44V3559 |
Power supplies, ac |
Un-Ex |
| |
8204-E8A, 9409-M50 |
42R6607 |
Power supplies, dc |
Un-Ex |
9406-MMA, 9117-MMA
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
9406-MMA, 9117-MMA |
10N8752 |
Service processor card (the SPCN function is built into the service processor card for this server) |
Un-P1-C11 |
| |
9406-MMA, 9117-MMA |
42R8010 |
Power supplies |
Un-Ex |
| |
9406-MMA, 9117-MMA |
42R7352 |
I/O Backplane |
Un-P1 |
5790, 7311-D11
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
5790, 7311-D11 |
22R3958 |
Power supplies |
Un-Ex |
| |
5790, 7311-D11 |
80P6626 |
I/O drawer backplane |
Un-P1 |
0595, 5095, 7311-D20
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
0595, 5095, 7311-D20 |
39J2781 |
Power supplies |
Un-Ex |
| |
0595, 5095, 7311-D20 |
39J0515 |
I/O drawer backplane |
Un-P1 |
5796, 7314-G30
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
5796, 7314-G30 |
10N8867 |
SPCN Card |
Un-P1-C8 |
| |
5796, 7314-G30 |
42R4491 |
Power supplies |
Un-Ex |
| |
5796, 7314-G30 |
10N7677 |
I/O drawer backplane |
Un-P1 |