FSPSP01

A part vital to system function has been deconfigured. Review the system error logs for errors that callout parts relevant to each reason code. If replacing those parts does not resolve the error, follow the procedure below.

Refer to Locating FRUs for instructions for removing and replacing any FRUs called out by the following procedure.

Perform the following steps:

  1. Is SRC B1xxB10C or B1xxB10D (xx indicates that the Subsystem ID is irrelevant)?
  2. Perform the following steps:
    1. Reseat all of the memory DIMMs on the system backplane but do not replace any memory DIMM at this time.
    2. Perform a slow boot, refer to Performing a slow boot.

    Does the problem persist?

  3. Use the following procedure to replace memory DIMMs, and perform a slow boot after each replacement until the problem is resolved. Memory DIMMs must be installed in quads and in the correct connectors. Refer to Physical Locations for information on memory DIMMs.
    1. Replace the first memory DIMM quad.
    2. Perform a slow boot, refer to Performing a slow boot .

    Does the problem persist?

  4. Use the following procedure to replace the system backplane.
    1. Replace the system backplane (Un-P1).
    2. Perform a slow boot, refer to Performing a slow boot .

    Does the problem persist?

  5. Is SRC B1xxB107 or B1xxB108?
  6. Is SCR B1xxB106?
  7. Is SRC B1xxB110 or B1xxB111?