The memory cards are plugged in an
invalid configuration and cannot be used by the system.
Refer
to Locating FRUs for instructions
for removing and replacing any FRUs called out by the following procedure.
Is the SRC B1xx C02A?
Yes: A memory module is missing from the system. The
additional parts in the FRU callout list will include all memory modules in
the group with the missing card. To correct the error, visually check the
system to determine which of these missing is missing, and add the module. This
ends the procedure.
No: Continue with the next step.
Is the SRC B1xx C029?
Yes: A memory module is a different type than the other
memory modules in the same group. The additional parts in the FRU callout
list will include all memory modules in the group that contain the error.
To correct the error, exchange the memory modules of the incorrect type with
those of the desired type. This ends the procedure.
No: Continue with the next step.
Is the SRC B1xx C02B?
Yes: A group of memory modules are missing and are required
so that other memory modules on the board can be configured. The additional
parts in the FRU callout list will include all missing memory modules in the
group. To correct the error, add or remove these modules to the desired locations. This
ends the procedure.
No: Continue with the next step.
Is the SRC B1xx C036?
Yes: A memory module isn't supported by this system.
The additional parts in the FRU callout list will include all memory modules
in the group that contains the unsupported modules. To correct the error,
remove these modules from the system or replace them with the correct type. This
ends the procedure.
No: Perform problem analysis using the SRC or contact
your next level of support. This ends the procedure.