PGDPART

  1. Power off the server. For information about how to power off the server, see the service guide for the server on which you are working.
  2. Verify that the service processor card, if present, is connected and seated correctly. See TWRCARD.
  3. Verify that the power supplies are connected and seated properly. See PWRSPLY.
  4. Power on the server.
  5. Is there a reference code 1xxx 2600?
    • No: Go to the next step.
    • Yes: Exchange the following FRUs one at a time:
      • SPCN card, service processor card, or system backplane (as appropriate for the server, see the following tables for FRUs for the server on which you are working)
      • Power supplies
      • Memory cards
      • Processor cards
      • Backplane

        Use the following tables to determine the part number for the field replaceable unit (FRU):

        8203-E4A

        CCIN or FFC Type and model Part number Description Location code
          8203-E4A 42R7898 System backplane Un-P1
          8203-E4A 44V4195 Power supplies, ac Un-Ex
        4520 8203-E4A 77P6497 512MB DDR2 memory card Un-P1-Cx
        4521 8203-E4A 77P6498 1GB DDR2 memory card Un-P1-Cx
        4522 8203-E4A 77P6499 2GB DDR2 memory card Un-P1-Cx
        4523 8203-E4A 77P6500 4GB DDR2 memory card Un-P1-Cx
        4524 8203-E4A 87H3621 8GB DDR2 memory card Un-P1-Cx
        2947 8203-E4A 77P7504 16GB DDR2 memory card Un-P1-Cx

        8204-E8A

        CCIN or FFC Type and model Part number Description Location code
          8204-E8A 10N9369 System backplane Un-P1
          8204-E8A 44V3559 Power supplies, ac Un-Ex
          8204-E8A 42R6607 Power supplies, dc Un-Ex
        4520 8204-E8A 77P6497 512MB DDR2 memory card Un-P1-Cx-Cy
        4521 8204-E8A 77P6498 1GB DDR2 memory card Un-P1-Cx-Cy
        4522 8204-E8A 77P6499 2GB DDR2 memory card Un-P1-Cx-Cy
        4523 8204-E8A 77P6500 4GB DDR2 memory card Un-P1-Cx-Cy
        4524 8204-E8A 87H3621 8GB DDR2 memory card Un-P1-Cx-Cy
        2947 8204-E8A 77P7504 16GB DDR2 memory card Un-P1-Cx-Cy
          8204-E8A 10N9377 4.2 GHz POWER6, 2 Core Processor Card Un-P1-Cx
          8204-E8A 10N9380 4.7 GHz POWER6, 2 Core Processor Card Un-P1-Cx

        9406-MMA, 9117-MMA

        CCIN or FFC Type and model Part number Description Location code
          9406-MMA, 9117-MMA 10N8752 Service processor card (the SPCN function is built into the service processor card for this system) Un-P1-C11
          9406-MMA, 9117-MMA 42R8010 Power supplies Un-Ex
        319B 9406-MMA, 9117-MMA 15R7433 512MB DDR2 memory card Un-P2-Cx-Cy
        319C 9406-MMA, 9117-MMA 15R7436 1GB DDR2 memory card Un-P2-Cx-Cy
        319E 9406-MMA, 9117-MMA 15R7439 2GB DDR2 memory card Un-P2-Cx-Cy
        319D 9406-MMA, 9117-MMA 15R7445 4GB DDR2 memory card Un-P2-Cx-Cy
        319F 9406-MMA, 9117-MMA 15R7448 8GB DDR2 memory card Un-P2-Cx-Cy
          9406-MMA, 9117-MMA 10N9146 3.5 GHz POWER6, 2 Core Processor Card Un-P2-Cx
          9406-MMA, 9117-MMA 10N9144 4.2 GHz POWER6, 2 Core Processor Card Un-P2-Cx
          9406-MMA, 9117-MMA 10N9139 4.7 GHz POWER6, 2 Core Processor Card Un-P2-Cx
          9406-MMA, 9117-MMA 42R7352 I/O Backplane Un-P1
          9406-MMA, 9117-MMA 10N8550 System processor backplane Un-P2

        5790, 7311-D11

        CCIN or FFC Type and model Part number Description Location code
          5790, 7311-D11 22R3958 Power supplies Un-Ex
          5790, 7311-D11 80P6626 I/O drawer backplane Un-P1

        0595, 5095, 7311-D20

        CCIN or FFC Type and model Part number Description Location code
          0595, 5095, 7311-D20 39J2781 Power supplies Un-Ex
          0595, 5095, 7311-D20 39J0515 I/O drawer backplane Un-P1

        5796, 7314-G30

        CCIN or FFC Type and model Part number Description Location code
          5796, 7314-G30 10N8867 SPCN Card Un-P1-C8
          5796, 7314-G30 42R4491 Power supplies Un-Ex
          5796, 7314-G30 10N7677 I/O drawer backplane Un-P1
  6. Is there a reference code 1xxx 2602?
    • No: Go to the next step.
    • Yes: Exchange the following FRUs one at a time:
      • Service processor card
      • Voltage regulators
      • Backplane

        Use the following tables to determine the part number for the field replaceable unit (FRU):

        9406-MMA, 9117-MMA

        CCIN or FFC Type and model Part number Description Location code
          9406-MMA, 9117-MMA 10N8752 Service processor card (the SPCN function is built into the service processor card for this system) Un-P1-C11
          9406-MMA, 9117-MMA 42R8325 Voltage regulators Un-P2-Cx (where x is equal to 3, 4, or 5)
          9406-MMA, 9117-MMA 42R7352 I/O Backplane Un-P1

        5790, 7311-D11

        CCIN or FFC Type and model Part number Description Location code
          5790, 7311-D11 22R3958 Power supplies Un-Ex
          5790, 7311-D11 80P6626 I/O drawer backplane Un-P1

        0595, 5095, 7311-D20

        CCIN or FFC Type and model Part number Description Location code
          0595, 5095, 7311-D20 39J2781 Power supplies Un-Ex
          0595, 5095, 7311-D20 39J0515 I/O drawer backplane Un-P1

        5796, 7314-G30

        CCIN or FFC Type and model Part number Description Location code
          5796, 7314-G30 42R4491 Power supplies Un-Ex
          5796, 7314-G30 10N8867 SPCN Card Un-P1-C8
          5796, 7314-G30 10N7677 I/O drawer backplane Un-P1
  7. Is there a reference code 2603?
    • No: This ends the procedure.
    • Yes: Exchange the following FRUs one at a time:
      • Service processor card
      • Power supplies
      • Backplane

        Use the following tables to determine the part number for the field replaceable unit (FRU):

        8203-E4A

        CCIN or FFC Type and model Part number Description Location code
          8203-E4A 42R7898 System backplane (the service processor is part of the sytem backplane for this server) Un-P1
          8203-E4A 44V4195 Power supplies, ac Un-Ex

        8204-E8A

        CCIN or FFC Type and model Part number Description Location code
          8204-E8A 10N9369 System backplane (the service processor is part of the sytem backplane for this server) Un-P1
          8204-E8A 44V3559 Power supplies, ac Un-Ex
          8204-E8A 42R6607 Power supplies, dc Un-Ex

        9406-MMA, 9117-MMA

        CCIN or FFC Type and model Part number Description Location code
          9406-MMA, 9117-MMA 10N8752 Service processor card (the SPCN function is built into the service processor card for this server) Un-P1-C11
          9406-MMA, 9117-MMA 42R8010 Power supplies Un-Ex
          9406-MMA, 9117-MMA 42R7352 I/O Backplane Un-P1

        5790, 7311-D11

        CCIN or FFC Type and model Part number Description Location code
          5790, 7311-D11 22R3958 Power supplies Un-Ex
          5790, 7311-D11 80P6626 I/O drawer backplane Un-P1

        0595, 5095, 7311-D20

        CCIN or FFC Type and model Part number Description Location code
          0595, 5095, 7311-D20 39J2781 Power supplies Un-Ex
          0595, 5095, 7311-D20 39J0515 I/O drawer backplane Un-P1

        5796, 7314-G30

        CCIN or FFC Type and model Part number Description Location code
          5796, 7314-G30 10N8867 SPCN Card Un-P1-C8
          5796, 7314-G30 42R4491 Power supplies Un-Ex
          5796, 7314-G30 10N7677 I/O drawer backplane Un-P1