PWR1918

A voltage regulator card might be failing.

Refer to Locating FRUs for instructions for removing and replacing any FRUs called out by the following procedure.

  1. Is the reference code 1xxx 8450?
  2. Is the reference code 1xxx 2630?
  3. Is the reference code 1xxx 2632?
  4. Is the reference code 1xxx 2633?
    1. System backplane (Un-P1)
    2. Ethernet card (Un-P1-C7)
    This ends the procedure.
  5. Is the reference code 1xxx 2634?
  6. Is the reference code 1xxx 2640?
  7. Is the reference code 1xxx 2642?
  8. Is the reference code 1xxx 2643?
    1. System backplane (Un-P1)
    2. Ethernet card (Un-P1-C7)
  9. Is the reference code 1xxx 2644?
  10. Is the reference code 1xxx 2622?
    1. Base RAID card (Un-P1-C10)
    2. Auxiliary RAID card (Un-P1-C9)
    3. System backplane (Un-P1)
    This ends the procedure.
  11. Is the reference code 1xxx 2623?
    1. Base RAID card (Un-P1-C10)
    2. Auxiliary RAID card (Un-P1-C9)
    This ends the procedure.
  12. Is the reference code 1xxx 2624?
    1. Ethernet card (Un-P1-C7)
    2. Base RAID card (Un-P1-C10)
    3. Auxiliary RAID card (Un-P1-C9)
    4. System backplane (Un-P1)
    5. DASD drives
    6. DASD and media backplane (Un-P2)
    This ends the procedure.
  13. Is the reference code 1xxx 2625?
    1. Ethernet card (Un-P1-C7)
    2. Base RAID card (Un-P1-C10)
    3. Auxiliary RAID card (Un-P1-C9)
    4. System backplane (Un-P1)
    5. TPMD card (Un-P1-C12)
    This ends the procedure.
  14. Is the reference code 1xxx 2626?
    1. Ethernet card (Un-P1-C7)
    This ends the procedure.
  15. Is the reference code 1xxx 3120?
    1. The VRM specified by the location code.
    2. The processor card specified by the location code.
    This ends the procedure.