PWR1920
Use this procedure to verify that the lights on the server control
panel and the display panel on all attached I/O expansion units are operating
correctly.
For important safety information before continuing with this procedure,
see Power isolation procedures.
Refer to Locating FRUs for
instructions for removing and replacing any FRUs called out by the following
procedure.
- Activate the lamp test by performing one of the following:
- Select function 04 lamp test on the control panel
and press Enter.
- Sign on to ASMI and click System Configuration -> Service Indicators
-> Lamp Test.
- Look at the server control panel and the display panels on all
attached I/O towers. The lamp test is active only for 25 seconds
after you press Enter. Check the following lights on the server control panel
and all I/O enclosures and towers:
- Power-on light.
- Attention light.
- All dots for the 32 character display.
Are all the lights on the control panel and the I/O display panels on?
- No: Go to step 4.
- Yes: These control panel lights are working correctly.
Continue with the next step.
- Are any abnormal characters or character patterns (not reference
codes or normal display mode) displayed?
- No: The lights are operating correctly.
This
ends the procedure.
- Yes: Continue with the next step.
-
Verify that all cables are seated correctly.
If the problem persists, replace the control panel. If the problem still persists,
use the following table to determine the possible causes for the lamp test
failure:
Table 39. Failing unit
| Failing unit |
FRU |
| 8204-E8A and 9409-M50 |
System backplane |
| 5088, 0588 |
Tower backplane assembly |
| 5094, 5294, 8094-002 |
Tower backplane assembly |
| 5095, 0595 |
Tower backplane assembly |
| 7311-D11, 7314-G30, 5790 or 5796 |
I/O backplane |
| 7311-D20 |
I/O backplane |