Explanation
The 2145 system assembly is failing.
Action
- Go to the light path diagnostic MAP and perform the light path diagnostic procedures.
- If the light path diagnostic procedure isolates the FRU, mark this error as "fixed" and go to the repair verification MAP.
If you have just replaced a FRU but it has not corrected the problem, ensure that the FRU is installed correctly and go to the next step.
- Replace the frame assembly.
- Check node status. If all nodes show a status of "online", mark the error that you have just repaired as "fixed".
If any nodes do not show a status of "online", go to the start MAP. If you return to this step, contact your support center to resolve the problem with the 2145.
- Go to the repair verification MAP.
Possible Cause-FRUs or other:
2145-8G4
- The FRUs that are indicated by the Light path diagnostics (98%)
- System board (2%)
2145-8F2 or 2145-8F4
- The FRUs that are indicated by the Light path diagnostics (98%)
- Frame assembly (2%)
2145-4F2
N/A