1070 One of the four fan assemblies that cool the processors has returned a status of Failed status through the service processor.

Explanation

One of the four fan assemblies that cool the processors has returned a status of Failed status through the service processor.

Action

  1. Check the error log and verify which fan failed.
  2. In the sequence shown, exchange the FRUs for new FRUs. See "Possible Cause-FRUs or other" after the last action in this section.
  3. Check node status. If all nodes show a status of "online", mark the error that you have just repaired "fixed". If any nodes do not show a status of "online", go to start MAP. If you return to this step, contact your support center to resolve the problem with the 2145.
  4. Go to repair verification MAP.

Possible Cause-FRUs or other:

2145-8F2 or 2145-8F4 or 2145-8G4

N/A

2145-4F2
  • Microprocessor fan (90%)
  • System board assembly (10%)