1076 The internal temperature sensor of the 2145 has reported that the temperature warning threshold has been exceeded.

Explanation

The internal temperature sensor of the 2145 has reported that the temperature warning threshold has been exceeded.

Action

  1. Check whether the internal airflow of the 2145 has been obstructed. Clear any obstructions. If you cannot find an obstruction, exchange the FRU for a new FRU. See "Possible Cause-FRUs or other" after the last action in this section.
  2. Check node status. If all nodes show a status of "online", mark the error that you have just repaired "fixed". If any nodes do not show a status of "online", go to start MAP. If you return to this step, contact your support center to resolve the problem with the 2145.
  3. Go to repair verification MAP.

Possible Cause-FRUs or other:

2145-8F2 or 2145-8F4 or 2145-8G4

N/A

2145-4F2

System board assembly (100%)