Explanation
The temperature soft or hard shutdown threshold of the 2145 has been exceeded. The 2145 has automatically powered off.
Action
- Ensure that the operating environment meets specifications.
- Ensure that the airflow is not obstructed.
- Ensure that the fans are operational.
- Go to the light path diagnostic MAP and perform the light path diagnostic procedures.
- Check node status. If all nodes show a status of "online", mark the error that you have just repaired as "fixed". If any nodes do not show a status of "online", go to the start MAP. If you return to this step, contact your support center to resolve the problem with the 2145.
- Go to the repair verification MAP.
Possible Cause-FRUs or other:
2145-8G4 or 2145-8A4
- The FRU that is indicated by the Light path diagnostics (25%)
- System board (5%)
2145-8F2 or 2145-8F4
- The FRU that is indicated by the Light path diagnostics (25%)
- Frame assembly (5%)
2145-4F2
N/A
Other:
System environment or airflow blockage (70%)