1093 The internal temperature sensor of the 2145 has reported that the temperature warning threshold has been exceeded.

Explanation

The internal temperature sensor of the 2145 has reported that the temperature warning threshold has been exceeded.

Action

  1. Ensure that the internal airflow of the node has not been obstructed.
  2. Check node status. If all nodes show a status of "online", mark the error that you have just repaired "fixed". If any nodes do not show a status of "online", go to the start MAP. If you return to this step, contact your support center to resolve the problem with the 2145.
  3. Go to repair verification MAP.

Possible Cause-FRUs or other:

2145-8G4 or 2145-8A4

2145-8F2 or 2145-8F4

2145-4F2

N/A

Other:

Airflow blockage (70%)