1122 A high speed SAS adapter error has occurred.

Explanation

The high speed SAS adapter has detected a PCI bus error and requires service before it can be restarted. The high speed SAS adapter failure has caused all of the solid state drives that were being accessed through this adapter to go Offline.

Action

If this is the first time that this error has occurred on this node:

  1. Power off the node.
  2. Reseat the high speed SAS adapter card.
  3. Power on the node.
  4. Submit the 'svcinfo lsmdisk' task and ensure that all of the solid state drive managed disks that are located in this node have a status of Online.

If the sequence of actions above has not resolved the problem or the error occurs again on the same node:

  1. In the sequence shown, exchange the FRUs for new FRUs. See "Possible Cause-FRUs or other" after the last action in this section.
  2. Submit the 'svcinfo lsmdisk' task and ensure that all of the solid state drive managed disks that are located in this node have a status of Online.
  3. Go to the repair verification MAP.

Possible Cause-FRUs or other:

  1. High speed SAS adapter (90%)
  2. System board (10%)
Library | Support | Terms of use | Feedback