1146 The signal connection between a 2145 and its 2145 UPS-1U is failing.

Explanation

The signal connection between a 2145 and its 2145 UPS-1U is failing.

Action

  1. Exchange the FRUs for new FRUs in the sequence shown. See "Possible Cause-FRU or other" after the last action in this section.
  2. Check node status. If all nodes show a status of "online", mark the error that you have just repaired as "fixed". If any nodes do not show a status of "online", go to start MAP. If you return to this step, contact your support center to resolve the problem with the uninterruptible power supply.
  3. Go to repair verification MAP.

Possible Cause-FRUs or other:

2145-8G4

2145-8F2 or 2145-8F4

2145-4F2