1625 Incorrect disk controller configuration.

Explanation

While running an MDisk discovery, the SAN Volume Controller has detected that a disk controller's configuration is not supported by SAN Volume Controller. The disk controller might appear to be operating with SAN Volume Controller; however, the configuration detected can potentially cause issues and should not be used. The unsupported configuration is shown in the event data.

Action

  1. Use the event data to determine changes required on the disk controller and reconfigure the disk controller to use a supported configuration.
  2. Mark the error that you have just repaired as "fixed". If the problem has not been fixed it will be logged again by the managed disk discovery that automatically runs at this time; this could take a few minutes.
  3. Go to repair verification MAP.

Possible Cause-FRUs or other:

Other:

Library | Support | Terms of use | Feedback