215 A problem has occurred with the uninterruptible power supply load.

Explanation

The 2145 detected that the current of the 2145 UPS exceeds the current that four 2145s require.

Action

  1. Ensure also that only 2145s are receiving power from the 2145 UPS; that is, no switches or disk controllers are connected to the 2145 UPS.
  2. If only one 2145 is connected to the 2145 UPS, exchange the FRU for a new FRU. See "Possible Cause-FRU or other." If more than one 2145 is connected to the 2145 UPS, disconnect the 2145s from the 2145 UPS and reconnect them one-at-a-time. While the problem persists, the nodes fail to start with boot error code 215 displayed on the 2145 front panel. When the first failure occurs, exchange the FRU for a new FRU. See "Possible Cause-FRU or other."

Possible Cause-FRUs or other: