Explanation
An excessive number of errors has been reported by the node's internal disk drive. It is no longer safe to rely on the integrity of the disk drive.
The node has removed itself from the cluster.
Action
Perform the following actions in order:
- Replace the node's disk drive assembly.
- Restart the node using the node rescue procedure.
- Delete the node from the cluster, then add the node back into the cluster.
- This error will not recur immediately when the node is restarted. If the error has occurred previously on this node and the disk drive has been replaced, replace FRUs in the order shown.
FRU list:
2145-8G4 or 2145-8A4
- Disk drive assembly (95%)
- Disk drive cables (5%)
2145-8F2 or 2145-8F4
- Disk drive assembly (100%)
2145-4F2
- Disk drive assembly (95%)
- SCSI signal cable (5%)