The cable retention bracket ensures
that the SAN Volume Controller 2145-8G4 node
does not mistakenly become unplugged from the uninterruptible
power supply.
The
SAN Volume Controller 2145-8G4 comes
with a cable retention bracket that attaches
to the back of the node. The cable retention bracket is connected
with the
screws that already hold the rear plate of the power supply in place.
Figure 1. SAN Volume Controller 2145-8G4 cable
retention bracket - type A
Install the SAN Volume Controller 2145-8G4 cable
retention bracket after you install the node
in the rack.
To attach the bracket, perform the
following steps:
- With the node powered
off and the power cable removed, unscrew
and remove the two screws
on the right side of the
rear plate that covers
the power supply fan unit, as shown in Figure 3. Figure 2. The SAN Volume Controller 2145-8G4 before
you attach the cable-retention bracket
- Insert the power cable.
- Position the cable retention bracket so that the power
cable runs
through the slot in the bracket, as shown in Figure 3.
Align the screw holes in the bracket with the holes that are in the
rear plate
where you removed the two screws.
- Replace the
top screw.
- Move the power supply handle back
into place over the retention
bracket, and replace the lower screw so that it holds the power supply
handle,
cable retention bracket, and power supply rear plate in place.
Figure 3. The SAN Volume Controller 2145-8G4 with
the cable-retention bracket attached