The cable-retention bracket ensures that
the SAN Volume Controller 2145-8A4 node
does not mistakenly become unplugged
from the uninterruptible
power supply.
The SAN Volume Controller 2145-8A4 cable-retention
bracket attaches to
the back of the SAN Volume Controller 2145-8A4 node.
It is connected with one screw
that already holds the rear plate of the power supply in place.
Install the SAN Volume Controller 2145-8A4 cable-retention
bracket after you install
the node in the rack.
To attach the bracket, perform the following
steps:
- Insert the power cable in the node.
- Unscrew the retaining screw 1 that
is located next to the power cable socket three full turns, but do
not fully remove the screw,
as shown in Figure 1.
Figure 1. Retaining screw
on the SAN Volume Controller 2145-8A4 node
- Slide the bracket
jaw over the power cable.
- Slide the bracket
down the cable until it is next to the power plug and slightly to
the right of where it needs to be.
- Place
the bottom lip of the retention bracket in the node chassis as shown
in Figure 2. Turn the bracket at a slight
angle, squeeze the top and bottom together, and position the top lip
in place behind the chassis back plate.
Figure 2. Installing the SAN Volume Controller 2145-8A4 cable
retention bracket
- Slide
the bracket to the left until the side lip of the retention bracket
goes behind the screw. Tighten the screw shown
in Figure 3.
Figure 3. SAN Volume Controller 2145-8A4 with
the cable-retention bracket installed