Before you connect the SAN Volume Controller 2145-CF8 to
the SAN, you must connect the Ethernet and fibre-channel cables.
Before you begin this task, see the customer's
cable-connection table to find out where to connect the Ethernet and
fibre-channel cables.
One or two Ethernet cables can be connected to the SAN Volume Controller 2145-CF8.
The customer's cable connection table indicates the number of
cables to connect. If only one cable is connected, the cable must
be connected to Ethernet port 1.
To connect the SAN Volume Controller 2145-CF8 to
the SAN and to the Ethernet network, perform the following steps:
- Connect the Ethernet cables
to Ethernet port 1, as shown by 8 in Figure 1 and Ethernet
port 2 ( 7 ).
- Connect the other
end of the Ethernet cable to the proper connector on the Ethernet
hub or switch.
Figure 1. Connectors on the rear of the SAN Volume Controller 2145-CF8
- 1 Fibre-channel port 1
- 2 Fibre-channel port 2
- 3 Fibre-channel port 3
- 4 Fibre-channel port 4
- 5 Power supply connectors
- 6 Serial port
- 7 Ethernet port 2
- 8 Ethernet port 1
Attention: When routing the fibre-channel
cables, do not tighten the cable straps or bend the cables to a radius
smaller than 76 mm (3 in.).
- Connect the fibre-channel
cables to the fibre-channel ports as required by the user's configuration.
- Connect the other ends of the fibre-channel cables
to the proper connectors of the fibre-channel switches.