Connect the SAN Volume Controller to
the 2145 UPS to
protect your data in the event of an unexpected loss of external power.
Attention: The SAN
Volume Controller 2145-4F2 node
is supported only in SAN Volume Controller 4.3.1
and earlier releases.
Each SAN
Volume Controller 2145-4F2 of
a pair must be connected to a different 2145 UPS.
Each 2145 UPS can
support up to two SAN
Volume Controller 2145-4F2 nodes.
Attention: Do not connect two nodes to the same pair of 2145 UPS units.
Both nodes are lost in the event that a power failure occurs on both
of those 2145 UPS units.
Note: You
must install 2145 UPS units
in pairs. There must be at least two 2145 UPS units
per cluster. A cluster can contain no more than eight SAN
Volume Controller 2145-4F2 nodes.
Also, ensure that each 2145 UPS of
a pair is connected to a separate electrical input power source (if
possible) to reduce the chance of input power failure at both 2145 UPS units.
Before
you begin this task, see the completed user's cable connection table,
which is described in the IBM® System Storage® SAN Volume Controller
Planning Guide and
was downloaded from www.ibm.com/storage/support/2145,
to identify the 2145 UPS to
which this node is to be connected.
Click
the Plan/upgrade tab. Under Sizing/Capacity, click SAN
Volume Controller planning. Click your language to view the Planning
Guide abstract. The charts and tables are located under the Related
information heading.
Perform
the following steps to connect the SAN
Volume Controller 2145-4F2 node
to the 2145 UPS:
- At the back of the SAN
Volume Controller 2145-4F2 node,
as shown in Figure 1,
plug a power cable into the power connector
. Figure 1. Connecting
the SAN
Volume Controller 2145-4F2 power
cable to the 2145 UPS
Power
connector
Serial
connector
Output connector
Signal
cable connector
- Plug the signal cable of the power cable assembly into
the serial connector
. DANGER
You have
already switched on the 2145 UPS.
The output sockets of the 2145 UPS are
live.
- Place the other end of the SAN
Volume Controller 2145-4F2 power
cable into any vacant output connector
on the 2145 UPS.
- Place the other end of the signal cable into any vacant
position on the top row of serial connectors
on the 2145 UPS. Attention: Do not plug any signal cables into the
bottom row of signal cable connectors or the 2145 UPS malfunctions.
The SAN
Volume Controller 2145-4F2 power
is now connected to the 2145 UPS.