The following steps provide the supported options and
impact on the SAN Volume Controller cluster:
The following limitations apply to partitions:
- Only one IBM System Storage DS5000 or IBM DS4000 system
storage partition that contains any of the ports of any of the nodes
in a single SAN Volume Controller cluster
can be created.
- Only map one partition to any of the ports on any of the nodes
that are in the SAN Volume Controller cluster
to avoid unexpected behavior. For example, you can lose access to
your storage or you might not receive warning messages, even if there
are errors logged in the SAN Volume Controller error
log.
The following limitation applies to
IBM System Storage DS5000 and
IBM DS4000 Copy
Services:
- Do not use IBM System Storage DS5000 or IBM DS4000 Copy
Services when the SAN Volume Controller cluster
is attached to an IBM System Storage DS5000 or IBM DS4000 system.
- You can use partitioning to allow IBM System Storage DS5000 or IBM DS4000 Copy
Services usage for other hosts.
The following information applies to the access LUN (also
known as the Universal Transport Mechanism (UTM) LUN):
- The access/UTM LUN is a special LUN that allows a IBM System Storage DS5000 or IBM DS4000 system
to be configured through software over the fibre-channel connection.
The access/UTM LUN does not have to be in the partition that contains
the SAN Volume Controller ports
because the access/UTM LUN is not required by the SAN Volume Controller cluster.
No errors are generated if the access/UTM LUN is not in the partition.
The following information applies to the logical unit
(LU):
- The SAN Volume Controller cluster
attempts to follow the preferred ownership that is specified by the IBM System Storage DS5000 or IBM DS4000 system.
You can specify which controller (A or B) is used for I/O operations
to an LU.
- If the SAN Volume Controller cluster
can see the ports of the preferred controller and error conditions
do not exist, the SAN Volume Controller cluster
accesses the LU through one of the ports on the preferred controller.
- If error conditions exist, the SAN Volume Controller cluster
ignores the preferred ownership of the IBM System Storage DS5000 or IBM DS4000 system.