To provide redundancy and concurrent maintenance, you must install the SAN Volume Controller nodes in pairs.
SAN Volume Controller provides a cable bundle for connecting uninterruptible power supply to a node. For 2145-8F2, 2145-8F4, 2145-8G4, and 2145-8A4, this is a single power cable plus a serial cable. For 2145-CF8, this is a dual-power cable plus serial cable. This cable is used to connect both power supplies of a node to the same uninterruptible power supply.
The SAN Volume Controller software determines whether the input voltage to the uninterruptible power supply is within range and sets an appropriate voltage alarm range on the uninterruptible power supply. The software continues to recheck the input voltage every few minutes. If it changes substantially but remains within the permitted range, the alarm limits are readjusted.