The IBM® DS6000™ provides
functions that are compatible with the SAN Volume Controller.
After you have defined at least one storage complex, storage
unit, and I/O port, you can define the SAN Volume Controller as
a host and create host connections. If you have not defined all of
these required storage elements, use the IBM System Storage® DS6000 Storage Manager or
the IBM DS6000 command-line
interface (CLI) to define these elements and return to this topic
after they are configured.
This task assumes that you have already
launched the IBM System Storage DS6000 Storage Manager.
Perform the following steps to configure the IBM DS6000:
- Click .
- Select Create from the Select
Action list. The Create Host System wizard is displayed.
- Perform the following steps to select a host type:
- Select IBM SAN Volume Controller (SVC) from
the Host Type list.
- Enter a unique name of up to 16 characters for each
port in the Nickname field. The value that
you enter in this field appears in other panels when you select defined
hosts. This is a required field.
- Optionally, enter a detailed description of up to 256
characters in the Description field.
- Click Next. The Define host wizard
panel is displayed.
- Perform the following steps in the Define host panel:
- Enter the number of ports that you are defining for
the SAN Volume Controller node
in the Quantity field.
Note: You
must add all of the SAN Volume Controller node
ports.
- Select FC Switch fabric (P-P) from
the Attachment Port Type list.
- Click Add.
- Select Group ports to share a common set
of volumes.
- Click Next. The Define host WWPN
panel is displayed.
- Specify a WWPN for each SAN Volume Controller node
port that you are configuring. After you have defined all SAN Volume Controller node
port WWPNs, click Next.
- Perform the following steps in the Specify storage units
panel:
- Select all the available storage units that use the
ports that you defined in step 5.
- Click Add to move the selected
storage units to the Selected storage units field.
- Click Next. The Specify storage
units parameters panel is displayed
- Perform the following steps in the Specify storage units
parameters panel:
- Select a host attachment identifier from the table.
- Click the following specific storage unit
I/O ports in the This host attachment can login
to field. The available ports are displayed in the Available
storage unit I/O ports table.
- Select each port in the Available storage unit I/O ports
table.
Note: The Type for each port should be FcSf.
If the listed type is not FcSf, click Configure I/O Ports.
The Configure I/O Ports panel is displayed. Click the port that you
want to configure and select Change to FcSf from
the Select Action list.
- Click Apply assignment.
- Click OK. The Verification panel
is displayed.
- Verify that the attributes and values that are displayed
in the table are correct.
- Click Finish if the values that
are displayed in the table are correct. Otherwise, click Back to
return to the previous panels and change the values that are not correct.