Logical unit (LU) settings are configurable at the LU level.
Table 1 lists the options that must be set for each LU that is accessed by the SAN Volume Controller. LUs that are accessed by hosts can be configured differently.
| Option | EMC CLARiiON default setting | SAN Volume Controller required setting |
|---|---|---|
| LU ID | Auto | N/A |
| RAID Type | 5 | Any RAID Group |
| RAID Group | Any available RAID Group | Any available RAID Group |
| Offset | 0 | Any setting |
| LU Size | ALL LBAs in RAID Group | Any setting |
| Placement | Best Fit | Either Best Fit or First Fit |
| UID | N/A | N/A |
| Default Owner | Auto | N/A |
| Auto Assignment | Disabled | Disabled |
| Verify Priority | ASAP | N/A |
| Rebuild Priority | ASAP | N/A |
| Strip Element Size | 128 | N/A |
| Read Cache Enabled | Enabled | Enabled |
| Write Cache Enabled | Enabled | Enabled |
| Idle Threshold | 0–254 | 0–254 |
| Max Prefetch Blocks | 0–2048 | 0–2048 |
| Maximum Prefetch IO | 0–100 | 0–100 |
| Minimum Prefetch Size | 0–65534 | 0–65534 |
| Prefetch Type | 0, 1, or 2 | 0, 1, or 2 |
| Prefetch Multiplier | 0 to 2048 or 0 to 324 | 0 to 2048 or 0 to 324 |
| Retain prefetch | Enabled or Disabled | Enabled or Disabled |
| Prefetch Segment Size | 0 to 2048 or 0 to 32 | 0 to 2048 or 0 to 32 |
| Idle Delay Time | 0 to 254 | 0 to 254 |
| Verify Priority | ASAP, High, Medium, or Low | Low |
| Write Aside | 16 to 65534 | 16 to 65534 |