Error codes provide a unique entry to service procedures. Each error code has an error ID that uniquely identifies the condition that caused the error.
Table 1 lists the error codes and corresponding error IDs.
| Error ID | Notification type | Condition | Error Code |
|---|---|---|---|
| 009020 | E | An automatic cluster recovery has started. All configuration commands are blocked. | 1001 |
| 009040 | E | The error event log is full. | 1002 |
| 009052 | E | The following causes are possible:
|
1195 |
| 009100 | W | The software install process has failed. | 2010 |
| 009101 | W | The software upgrade package delivery has failed. | 2010 |
| 009110 | W | Software installation process stalled due to lack of redundancy. | 2010 |
| 009115 | W | A software downgrade has failed. | 2008 |
| 009150 | W | Unable to connect to the SMTP (e-mail) server | 2600 |
| 009151 | W | Unable to send mail through the SMTP (e-mail) server | 2601 |
| 009170 | W | The Metro Mirror or Global Mirror feature capacity is not set. | 3030 |
| 009171 | W | The FlashCopy® feature capacity is not set. | 3031 |
| 009172 | W | The Virtualization feature has exceeded the amount that is licensed. | 3032 |
| 009173 | W | The FlashCopy feature has exceeded the amount that is licensed. | 3032 |
| 009174 | W | The Metro Mirror or Global Mirror feature has exceeded the amount that is licensed. | 3032 |
| 009176 | W | The value set for the virtualization feature capacity is not valid. | 3029 |
| 009177 | W | A physical disk FlashCopy feature license is required. | 3035 |
| 009178 | W | A physical disk Metro Mirror and Global Mirror feature license is required. | 3036 |
| 009179 | W | A virtualization feature license is required. | 3025 |
| 009180 | E | Automatic recovery of offline node failed. | 1194 |
| 009181 | W | Unable to send e-mail to any of the configured e-mail servers. | 3081 |
| 010002 | E | The node ran out of base event sources. As a result, the node has stopped and exited the cluster. | 2030 |
| 010003 | W | The number of device logins has reduced. | 1630 |
| 010006 | E | A software error has occurred. | 2030 |
| 010008 | E | The block size is invalid, the capacity or LUN identity has changed during the managed disk initialization. | 1660 |
| 010010 | E | The managed disk is excluded because of excessive errors. | 1310 |
| 010011 | E | The remote port is excluded for a managed disk and node. | 1220 |
| 010012 | E | The local port is excluded. | 1210 |
| 010013 | E | The login is excluded. | 1230 |
| 010017 | E | A timeout has occurred as a result of excessive processing time. | 1340 |
| 010018 | E | An error recovery procedure has occurred. | 1370 |
| 010019 | E | A managed disk I/O error has occurred. | 1310 |
| 010020 | E | The managed disk error count threshold has exceeded. | 1310 |
| 010021 | E | There are too many devices presented to the cluster. | 1200 |
| 010022 | E | There are too many managed disks presented to the cluster. | 1200 |
| 010023 | E | The are too many LUNs presented to a node. | 1200 |
| 010025 | W | A disk I/O medium error has occurred. | 1320 |
| 010026 | E | There are no managed disks that can be used as a quorum disk. | 1330 |
| 010027 | E | The quorum disk is not available. | 1335 |
| 010028 | W | A controller configuration is not supported. | 1625 |
| 010029 | E | A login transport fault has occurred. | 1360 |
| 010030 | E | A managed disk error recovery procedure (ERP)
has occurred. The node or controller reported the following:
|
1370 |
| 010031 | E | One or more MDisks on a controller are degraded. | 1623 |
| 010032 | W | The controller configuration limits failover. | 1625 |
| 010033 | E | The controller configuration uses the RDAC mode; this is not supported. | 1624 |
| 010034 | E | Persistent unsupported controller configuration. | 1695 |
| 010035 | W | A quorum disk is configured on the controller that is set to not allow quorum. | 1570 |
| 010040 | E | The controller system device is only connected to the node through a single initiator port. | 1627 |
| 010041 | E | The controller system device is only connected to the node through a single target port. | 1627 |
| 010042 | E | The controller system device is only connected to the cluster nodes through a single target port. | 1627 |
| 010043 | E | The controller system device is only connected to the cluster nodes through half of the expected target ports. | 1627 |
| 010044 | E | The controller system device has disconnected all target ports to the cluster nodes. | 1627 |
| 010050 | E | A solid-state drive (SSD) failed. A rebuild is required. | 1201 |
| 010051 | E | A solid-state drive (SSD) is missing. | 1202 |
| 010053 | E | A solid-state drive (SSD) is reporting a PFA. | 1215 |
| 010054 | E | A solid-state drive (SSD) is reporting too many errors. | 1215 |
| 010055 | E | An unrecognized SAS device. | 1665 |
| 010056 | E | SAS error counts exceeded the warning thresholds. | 1216 |
| 010057 | E | SAS errors exceeded critical thresholds. | 1216 |
| 010058 | E | A solid-state drive (SSD) initialization failed. | 1661 |
| 010059 | E | A solid-state drive (SSD) is offline due to excessive errors. | 1311 |
| 010060 | E | A solid-state drive (SSD) exceeded the warning temperature threshold. | 1218 |
| 010061 | E | A solid-state drive (SSD) exceeded the offline temperature threshold. | 1217 |
| 020001 | E | There are too many medium errors on the managed disk. | 1610 |
| 020002 | E | A managed disk group is offline. | 1620 |
| 020003 | W | There are insufficient virtual extents. | 2030 |
| 030000 | W | The trigger prepare command has failed because of a cache flush failure. | 1900 |
| 030010 | W | The mapping is stopped because of the error that is indicated in the data. | 1910 |
| 030020 | W | The mapping is stopped because of a cluster or complete I/O group failure, and the current state of the relationship could not be recovered. | 1895 |
| 050001 | W | The relationship is stopped because of a cluster or complete I/O group failure, and the current state of the mapping could not be recovered. | 1700 |
| 050002 | W | A Metro Mirror or Global Mirror relationship or consistency group exists within a cluster, but its partnership has been deleted. | 3080 |
| 050010 | W | A Metro Mirror or Global Mirror relationship has stopped because of a persistent I/O error. | 1920 |
| 050020 | W | A Metro Mirror or Global Mirror relationship has stopped because of an error that is not a persistent I/O error. | 1720 |
| 050030 | W | There are too many cluster partnerships. The number of cluster partnerships has been reduced. | 1710 |
| 050031 | W | There are too many cluster partnerships. The cluster has been excluded. | 1710 |
| 060001 | W | The space-efficient virtual disk copy is offline because there is insufficient space. | 1865 |
| 060002 | W | The space-efficient virtual disk copy is offline because the metadata is corrupt. | 1862 |
| 060003 | W | The space-efficient virtual disk copy is offline because the repair has failed. | 1860 |
| 062001 | W | Unable to mirror medium error during VDisk copy synchronization | 1950 |
| 062002 | W | The mirrored VDisk is offline because the data cannot be synchronized. | 1870 |
| 062003 | W | The repair process for the mirrored disk has stopped because there is a difference between the copies. | 1600 |
| 072001 | E | A system board hardware failure has occurred. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1020 |
| 072004 | E | A CMOS battery failure has occurred. This error applies to the SAN Volume Controller 2145-4F2, the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1670 |
| 072005 | E | A CMOS battery failure has occurred. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1670 |
| 072006 | E | A CMOS battery failure has occurred. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1670 |
| 072007 | E | A CMOS battery failure has occurred. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1670 |
| 072101 | E | The processor is missing. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1025 |
| 072102 | E | The processor is missing. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1025 |
| 073001 | E | The fibre-channel adapter card has detected an incorrect number of fibre-channel adapters. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1010 |
| 073002 | E | The fibre-channel adapter has failed. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1050 |
| 073003 | E | The fibre-channel ports are not operational. | 1060 |
| 073004 | E | The fibre-channel adapter has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1012 |
| 073005 | E | A cluster path failure has occurred. | 1550 |
| 073006 | W | The SAN is not correctly zoned. As a result, more than 512 ports on the SAN have logged into one SAN Volume Controller port. | 1800 |
| 073101 | E | The 2-port fibre-channel adapter card in slot 1 is missing. This error applies to only the SAN Volume Controller 2145-8F2 model. | 1014 |
| 073102 | E | The 2-port fibre-channel adapter in slot 1 has failed. This error applies to only the SAN Volume Controller 2145-8F2 model. | 1054 |
| 073104 | E | The 2-port fibre-channel adapter in slot 1 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-8F2 model. | 1017 |
| 073201 | E | The 2-port fibre-channel adapter in slot 2 is missing. This error applies to only the SAN Volume Controller 2145-8F2 model. | 1015 |
| 073202 | E | The 2-port fibre-channel adapter in slot 2 has failed. This error applies to only the SAN Volume Controller 2145-8F2 model. | 1056 |
| 073204 | E | The 2-port fibre-channel adapter in slot 2 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-8F2 model. | 1018 |
| 073251 | E | The 4-port fibre-channel adapter in slot 1 is missing. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1011 |
| 073252 | E | The 4-port fibre-channel adapter in slot 1 has failed. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1055 |
| 073258 | E | The 4-port fibre-channel adapter in slot 1 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1013 |
| 073261 | E | The 4-port fibre-channel adapter in slot 1 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1011 |
| 073262 | E | The 4-port fibre-channel adapter in slot 1 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1055 |
| 073268 | E | The 4-port fibre-channel adapter in slot 1 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1013 |
| 073271 | E | The 4-port fibre-channel adapter in slot 1 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1011 |
| 073272 | E | The 4-port fibre-channel adapter in slot 1 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1055 |
| 073278 | E | The 4-port fibre-channel adapter in slot 1 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1013 |
| 073301 | E | The 4-port fibre-channel adapter in slot 2 is missing. This error applies to only the SAN Volume Controller 2145-8F4 model. | 1016 |
| 073302 | E | The 4-port fibre-channel adapter in slot 2 has failed. This error applies to only the SAN Volume Controller 2145-8F4 model. | 1057 |
| 073304 | E | The 4-port fibre-channel adapter in slot 2 has detected a PCI bus error. This error applies to only the SAN Volume Controller 2145-8F4 model. | 1019 |
| 073305 | E | One or more fibre-channel ports are running at a speed that is lower than the last saved speed. | 1065 |
| 073310 | E | A duplicate fibre-channel frame has been detected, which indicates that there is an issue with the fibre-channel fabric. Other fibre-channel errors might also be generated. | 1203 |
| 074001 | W | Unable to determine the vital product data (VPD) for an FRU. This is probably because a new FRU has been installed and the software does not recognize that FRU. The cluster continues to operate; however, you must upgrade the software to fix this warning. | 2040 |
| 074002 | E | The node warm started after a software error. | 2030 |
| 075001 | E | The flash boot device has failed. This error applies to the SAN Volume Controller 2145-4F2, SAN Volume Controller 2145-8F2, and the SAN Volume Controller 2145-8F4 models.This error applies to the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1040 |
| 075002 | E | The flash boot device has recovered. This error applies to the SAN Volume Controller 2145-4F2, SAN Volume Controller 2145-8F2, and the SAN Volume Controller 2145-8F4 models.This error applies to the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1040 |
| 075005 | E | A service controller read failure has occurred. This error applies to the SAN Volume Controller 2145-4F2, SAN Volume Controller 2145-8F2, and the SAN Volume Controller 2145-8F4 models.This error applies to the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1044 |
| 075011 | E | The flash boot device has failed. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1040 |
| 075012 | E | The flash boot device has recovered. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1040 |
| 075015 | E | A service controller read failure has occurred. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1044 |
| 075021 | E | The flash boot device has failed. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1040 |
| 075022 | E | The flash boot device has recovered. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1040 |
| 075025 | E | A service controller read failure has occurred. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1044 |
| 075031 | E | The flash boot device has failed. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1040 |
| 075032 | E | The flash boot device has recovered. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1040 |
| 075035 | E | A service controller read failure has occurred. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1044 |
| 076001 | E | The internal disk for a node has failed. | 1030 |
| 076002 | E | The hard disk is full and cannot capture any more output. | 2030 |
| 076401 | E | One of the two power supply units in the node has failed. | 1096 |
| 076402 | E | One of the two power supply units in the node cannot be detected. | 1096 |
| 076403 | E | One of the two power supply units in the node is without power. | 1097 |
| 076501 | E | A high-speed SAS adapter is missing. | 1120 |
| 076502 | E | Degraded PCIe lanes on a high-speed SAS adapter. | 1121 |
| 076503 | E | A PCI bus error occurred on a high-speed SAS adapter. | 1121 |
| 076504 | E | A high-speed SAS adapter requires a PCI bus reset. | 1122 |
| 076505 | E | Vital product data (VPD) is corrupt on high-speed SAS adapter. | 1121 |
| 077001 | E | The system board service processor shows that fan 1 has failed. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1070 |
| 077002 | E | The system board service processor shows that fan 2 has failed. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1070 |
| 077003 | E | The system board service processor shows that fan 3 has failed. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1070 |
| 077004 | E | The system board service processor shows that fan 4 has failed. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1070 |
| 077005 | E | The system board service processor shows that fan 5 has failed. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1071 |
| 077011 | E | The system board service processor shows that the ambient temperature threshold has exceeded. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1075 |
| 077012 | E | The system board service processor shows that temperature warning threshold has exceeded. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1076 |
| 077013 | E | The system board service processor shows that the soft or hard shutdown temperature threshold has exceeded. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1077 |
| 077021 | E | The system board service processor shows that Voltage 1, (12 volt) is outside the set thresholds. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1080 |
| 077022 | E | The system board service processor shows that Voltage 2, (5 volt) is outside the set thresholds. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1080 |
| 077023 | E | The system board service processor shows that Voltage 3, (3.3 volt) is outside the set thresholds. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1080 |
| 077024 | E | The system board service processor shows that Voltage 4, (2.5 volt) is outside the set thresholds. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1081 |
| 077025 | E | The system board service processor shows that Voltage 5, (1.5 volt) is outside the set thresholds. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1081 |
| 077026 | E | The system board service processor shows that Voltage 6, (1.25 volt) is outside the set thresholds. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1081 |
| 077027 | E | The system board service processor shows that Voltage 7, (CPU volts) is outside the set thresholds. This error applies to only the SAN Volume Controller 2145-4F2 model. | 1081 |
| 077101 | E | The service processor shows a fan 40×40×28 failure. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1090 |
| 077102 | E | The service processor shows a fan 40×40×56 failure. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1091 |
| 077105 | E | The service processor shows a fan failure. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1089 |
| 077106 | E | The service processor shows a fan failure. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1089 |
| 077107 | E | The service processor shows a fan failure. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1089 |
| 077111 | E | The node ambient temperature threshold has exceeded. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1094 |
| 077112 | E | The node processor warning temperature threshold has exceeded. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1093 |
| 077113 | E | The node processor or ambient critical threshold has exceeded. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1092 |
| 077121 | E | System board - any voltage high. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1100 |
| 077124 | E | System board - any voltage low. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1105 |
| 077128 | E | A power management board voltage failure has occurred. This error applies to both the SAN Volume Controller 2145-8F2 and the SAN Volume Controller 2145-8F4 models. | 1110 |
| 077161 | E | The node ambient temperature threshold has exceeded. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1094 |
| 077162 | E | The node processor warning temperature threshold has exceeded. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1093 |
| 077163 | E | The node processor or ambient critical threshold has exceeded. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1092 |
| 077165 | E | The node ambient temperature threshold has exceeded. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1094 |
| 077166 | E | The node processor warning temperature threshold has exceeded. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1093 |
| 077167 | E | The node processor or ambient critical threshold has exceeded. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1092 |
| 077171 | E | System board - any voltage high. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1101 |
| 077172 | E | System board - any voltage high. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1101 |
| 077173 | E | System board - any voltage high. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1101 |
| 077174 | E | System board - any voltage low. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1106 |
| 077175 | E | System board - any voltage low. This error applies to only the SAN Volume Controller 2145-8A4 model. | 1106 |
| 077176 | E | System board - any voltage low. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1106 |
| 077178 | E | A power management board voltage failure has occurred. This error applies to only the SAN Volume Controller 2145-8G4 model. | 1110 |
| 077185 | E | The node ambient temperature threshold has exceeded. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1094 |
| 077186 | E | The node processor warning temperature threshold has exceeded. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1093 |
| 077187 | E | The node processor or ambient critical threshold has exceeded. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1092 |
| 077188 | E | A power management board voltage failure has occurred. This error applies to only the SAN Volume Controller 2145-CF8 model. | 1110 |
| 078001 | E | A power domain error has occurred. Both nodes in a pair are powered by the same uninterruptible power supply. | 1155 |
| 079000 | W | Data has not been recovered on virtual disks (VDisks). | 1850 |
| 079500 | W | The limit on the number of cluster secure shell (SSH) sessions has been reached. | 2500 |
| 079501 | W | Unable to access the Network Time Protocol (NTP) network time server. | 2700 |
| 081001 | E | An Ethernet port failure has occurred. | 1400 |
| 082001 | E | A server error has occurred. | 2100 |
| 083001 | E | An uninterruptible power supply communications failure has occurred. The RS232 connection between a node and its uninterruptible power supply is faulty. This error applies to only the 2145 UPS model. | 1145 |
| 083002 | E | The uninterruptible power supply output is unexpectedly high. The uninterruptible power supply is probably connected to a non-SAN Volume Controller load. This error applies to only the 2145 UPS model. | 1165 |
| 083003 | E | The uninterruptible power supply battery has reached end of life. This error applies to only the 2145 UPS model. | 1190 |
| 083004 | E | An uninterruptible power supply battery failure has occurred. This error applies to only the 2145 UPS model. | 1180 |
| 083005 | E | An uninterruptible power supply electronics failure has occurred. This error applies to only the 2145 UPS model. | 1170 |
| 083006 | E | Uninterruptible power supply frame fault. This error applies to only the 2145 UPS model. | 1175 |
| 083007 | E | Uninterruptible power supply frame fault overcurrent. This error applies to only the 2145 UPS model. | 1160 |
| 083008 | E | An uninterruptible power supply failure has occurred. This error applies to only the 2145 UPS model. | 1185 |
| 083009 | E | Uninterruptible power supply ac input power fault. This error applies to only the 2145 UPS model. | 1140 |
| 083010 | E | An uninterruptible power supply configuration error has occurred. This error applies to only the 2145 UPS model. | 1150 |
| 083011 | E | Uninterruptible power supply ambient over temperature. This error applies to only the 2145 UPS model. | 1135 |
| 083012 | E | Uninterruptible power supply over temperature warning. This error applies to only the 2145 UPS model. | 3000 |
| 083013 | E | The cross cable test was bypassed because of an internal uninterruptible power supply software error. This error applies to only the 2145 UPS model. | 3010 |
| 083101 | E | An uninterruptible power supply communications failure has occurred. The RS232 connection between a node and its uninterruptible power supply is faulty. This error applies to only the 2145 UPS-1U model. | 1146 |
| 083102 | E | The uninterruptible power supply output is unexpectedly high. The uninterruptible power supply is probably connected to a non-SAN Volume Controller load. This error applies to only the 2145 UPS-1U model. | 1166 |
| 083103 | E | The uninterruptible power supply battery has reached end of life. This error applies to only the 2145 UPS-1U model. | 1191 |
| 083104 | E | An uninterruptible power supply battery failure has occurred. This error applies to only the 2145 UPS-1U model. | 1181 |
| 083105 | E | An uninterruptible power supply electronics failure has occurred. This error applies to only the 2145 UPS-1U model. | 1171 |
| 083107 | E | Uninterruptible power supply overcurrent. This error applies to only the 2145 UPS-1U model. | 1161 |
| 083108 | E | An uninterruptible power supply failure has occurred. This error applies to only the 2145 UPS-1U model. | 1186 |
| 083109 | E | Uninterruptible power supply ac input power fault. This error applies to only the 2145 UPS-1U model. | 1141 |
| 083110 | E | An uninterruptible power supply configuration error has occurred. This error applies to only the 2145 UPS-1U model. | 1151 |
| 083111 | E | Uninterruptible power supply ambient over temperature. This error applies to only the 2145 UPS-1U model. | 1136 |
| 083112 | E | Uninterruptible power supply over temperature warning. This error applies to only the 2145 UPS-1U model. | 3001 |
| 083113 | E | An uninterruptible power supply software error has occurred. This error applies to only the 2145 UPS-1U model. | 3011 |