Replacing the SAN Volume Controller 2145-4F2 disk drive fan

The disk drive fan must be removed if it is defective or if it needs to be replaced.

Perform the following steps to replace the disk drive fan:

  1. Remove all power from the SAN Volume Controller 2145-4F2.
  2. Remove the SAN Volume Controller 2145-4F2 from the rack.
  3. Remove the top cover from the SAN Volume Controller 2145-4F2.
  4. Unplug the power cables connected to the system board.
  5. Remove the entire fan assembly number one, as shown in Figure 1, by sliding the right-hand side of the disk drive fan forward. Then, pull the assembly away from the clip.
    Figure 1. Removing a SAN Volume Controller 2145-4F2 disk drive fan
    Removing a disk drive fan
  6. Remove the fan from the bracket by pulling the sides of the bracket apart.
  7. Insert the new fan into the bracket by pulling the sides of the bracket apart.
  8. If you have any other tasks that you need to perform while the fan is removed, do those tasks now. Otherwise, reinstall the parts in the reverse sequence.
    Note:
    • The airflow is from the front to the back of the SAN Volume Controller 2145-4F2.
    • The fan cable comes out of the back of the fan. When you install a fan, ensure that the back of the fan is facing the back of the SAN Volume Controller 2145-4F2.