Port settings are configurable at the port level.
Restriction: Only one port per HSG80 pair can
be used with the SAN Volume Controller.
The port settings are set using the following commands:
- SET THIS PORT_1_TOPOLOGY=FABRIC
- SET THIS PORT_2_TOPOLOGY=FABRIC
- SET OTHER PORT_1_TOPOLOGY=FABRIC
- SET OTHER PORT_2_TOPOLOGY=FABRIC
These values can be checked using the following commands:
Table 1 lists
the HSG80 controller port settings that the SAN Volume Controller supports:
Table 1. HSG80 controller port settings
supported by the SAN Volume Controller| Option |
HSG80 default setting |
SAN Volume Controller required
setting |
| PORT_1/2-AL-PA |
71 or 72 |
Not applicable |
| PORT_1/2_TOPOLOGY |
Not defined |
FABRIC |
Note: The HP MA and EMA systems support LUN masking that is
configured with the SET unit number ENABLE_ACCESS_PATH command.
When used with a SAN Volume Controller,
the access path must be set to all ("SET unit number
ENABLE_ACCESS_PATH=ALL") and all LUN masking must be handled exclusively
by the SAN Volume Controller.
You can use the SHOW CONNECTIONS FULL command to check access
rights.