The MSA2000 System Storage® Management Utility (SMU) provides configuration settings and options that can be used with SAN Volume Controller clusters.
Table 1 describes the port settings that are supported by the SAN Volume Controller.
| Option | Values (any limits on the possible values) | Description |
|---|---|---|
| Host Port Configuration | 2 Gbps or 4 Gbps | Set according to the fabric speed. |
| Internal Host Port Interconnect | Straight-through | Set to Straight-through for a point-to-point fibre-channel connection. |
| Host Port Configuration | Point-to-Point | Set to Point-to-point for use with SAN Volume Controller. |
| Option | Value | Description |
|---|---|---|
| Expose to All Hosts | Yes | After the mapping of the volume to the SAN Volume Controller completes, this is modified to All other hosts (none no access). This can be done under the Assign Host Access Privileges frame. |
| Automatically assign LUNs | Yes | This forces option expose to all hosts and is necessary for consistent LUN numbering. |
| write-policy | write-back | |
| optimization | any | |
| read-ahead-size | default | |
| independent | disable | This setting controls cache mirroring. Because SAN Volume Controller requires mirroring, the independent=disable option must be used. |
There is no specific host option to present the MSA2000 systems to SAN Volume Controller clusters. Use Microsoft® Windows® 2003 (Microsoft Windows 2003) as the host setting for SAN Volume Controller.