Installing the SAN Volume Controller 2145-4F2 in a rack

After installing the support rails, you can install the SAN Volume Controller 2145-4F2 in the rack.

Attention: The SAN Volume Controller 2145-4F2 node is supported only in SAN Volume Controller 4.3.1 and earlier releases.
CAUTION:
To avoid any hazard from the rack tipping forward when devices are installed, observe all safety precautions for the rack into which you are installing the device.

Perform the following steps to install the SAN Volume Controller 2145-4F2 node in the rack:

  1. Stand at the front of the rack and place the back of the node onto the support rails, as low in the rack as possible.
  2. Slide the node fully into the rack.
  3. Fully tighten the two captive thumbscrews (number one in Figure 1).
    Figure 1. Installing the SAN Volume Controller 2145-4F2 into a rack
    Installing the SAN Volume Controller 2145-4F2 into a rack
  4. Repeat this procedure for each SAN Volume Controller 2145-4F2 node that needs to be installed.
    Tip: If you have available space, leave a 1U space between each node to improve the air circulation in the rack.