After installing the support rails, you can install the SAN
Volume Controller 2145-4F2 in
the rack.
Attention: The SAN
Volume Controller 2145-4F2 node
is supported only in SAN Volume Controller 4.3.1
and earlier releases.
CAUTION:
To
avoid any hazard from the rack tipping forward when devices are installed,
observe all safety precautions for the rack into which you are installing
the device.
Perform the following steps to install the SAN
Volume Controller 2145-4F2 node
in the rack:
- Stand at the front of the rack and place the back of the
node onto the support rails, as low in the rack as possible.
- Slide the node fully into the rack.
- Fully tighten the two captive thumbscrews (
in Figure 1). Figure 1. Installing the SAN
Volume Controller 2145-4F2 into
a rack
- Repeat this procedure for each SAN
Volume Controller 2145-4F2 node
that needs to be installed.
Tip: If
you have available space, leave a 1U space between each node to improve
the air circulation in the rack.