Port settings are configurable at the port level.
The settings listed in Table 1 apply to disk controllers that are in a switch zone that contains SAN Volume Controller nodes. If the system is shared between a SAN Volume Controller cluster and another host, you can configure with different settings than shown if both of the following conditions are true:
There are no available options with the scope of a single controller.
| Option | Default setting | SAN Volume Controller required setting |
|---|---|---|
| Host connection mode 1 | Standard | Standard |
| VxVM DMP mode (HDS Thunder 9200 only) | False | False |
| HP connection mode | False | False |
| Report inquiry page 83H (HDS Thunder 9200 only) | False | True |
| UA (06/2A00) suppress mode | False | True |
| HISUP mode | False | False |
| CCHS mode | False | False |
| Standard inquiry data expand (HDS Thunder 9200 only) | False | False |
| Host connection mode 2 | False | False |
| Product ID DF400 mode | False | False |
| HBA WWN report mode (HDS Thunder 9200 only) | False | False |
| NACA mode | False | False |
| SUN cluster connection mode | False | False |
| Persistent RSV cluster mode | False | False |
| ftServer connection mode 1 (HDS Thunder 9200 only) | False | False |
| ftServer connection mode 2 | False | False |
| SRC Read Command reject | False | False |
| Reset/LIP mode (signal) | False | False |
| Reset/LIP mode (progress) | False | False |
| Reset ALL LIP port mode | False | False |
| Reset target (reset bus device mode) | False | True |
| Reserve mode | False | True |
| Reset logical unit mode | False | True |
| Reset logout of third party process mode | False | False |
| Read Frame minimum 128 byte mode (HDS Thunder 950xxV only) | False | False |
| Topology | Point-to-point | Point-to-point |