Power button

The power button turns on or off the main power to the SAN Volume Controller 2145-4F2.

To turn on the power, press and release the power button.

To turn off the power, press and release the power button. For a preferred method of powering off, see MAP 5350: Powering off a SAN Volume Controller node.

Note: When the SAN Volume Controller is operational and you press and immediately release the power button, the SAN Volume Controller indicates on its front panel that it is powering off and writes its control data to its internal disk. This can take up to five minutes. If you press the power button but do not release it, an immediate power off occurs without the SAN Volume Controller control data being written to disk. Service actions are then required to make the SAN Volume Controller operational again. Therefore, during a power-off operation, do not press and hold the power button for more than two seconds.
Attention: The SAN Volume Controller 2145-4F2 node is the only SAN Volume Controller model that is supported by the 2145 UPS. If a SAN Volume Controller 2145-4F2 is turned off for more than five minutes and it is the only SAN Volume Controller 2145-4F2 that is connected to a 2145 UPS, the 2145 UPS also turns off. To turn on the SAN Volume Controller 2145-4F2, you must first turn on the 2145 UPS to which it is connected.
Note: The 2145 UPS-1U does not turn off when the SAN Volume Controller node is shut down from the power button.