If the master console hardware option is included with the SAN Volume Controller, ensure that your physical site meets the installation requirements for the master console hardware and the console monitor kit.
The following tables provide the physical characteristics and the environmental requirements for the master console hardware option:
Ensure that space is available in a rack that is capable of supporting the master console.
| Height | Width | Depth | Maximum Weight |
|---|---|---|---|
44 mm |
480 mm |
426 mm |
12.7 kg |
Ensure that space is also available in the rack for the master console kit.
| Height | Width | Depth | Maximum Weight |
|---|---|---|---|
40 mm |
480 mm |
530 mm |
17.0 kg |
Ensure that your environment meets the following ac power and voltage requirements:
| Power Supply | Electrical Input |
|---|---|
| 203 watt (110 or 220 V ac auto-sensing) | Sine-wave input (47–63 Hz) required |
Ensure that your environment falls within the following ranges:
| Environment | Temperature | Altitude | Relative Humidity |
|---|---|---|---|
| Server On | 10° to 35°C |
0 to 914 m |
8% to 80% |
| Server Off | -40°C to 60°C |
Maximum: |
8% to 80% |