You need to remove the riser-card assembly from the SAN Volume Controller 2145-8A4 node
and then remove the fibre-channel adapter assembly from the riser-card
assembly.
Perform the following steps to remove a fibre-channel adapter
assembly:
- Turn off the node while
ensuring that its data is mirrored and synchronized. See MAP 5350: Powering off a SAN Volume Controller node for
more information.
- Remove the cable-retention bracket and disconnect
the power cable from the node. See Removing the cable-retention bracket.
- Remove the node from the rack
and place it on a flat, static-protective surface. See Removing the SAN Volume Controller from a rack.
- Remove the top cover. See Removing the top cover.
- Grasp the riser-card assembly at the front and rear edges
and lift to remove it from the node. Place the riser-card assembly
shown in Figure 1 on
a flat, static-protective surface.
Figure 1. SAN Volume Controller 2145-8A4 riser-card
assembly
- Remove the four SFP connectors from
the adapter. To do this, unclip the release handle shown in Figure 2 and then use
the handle to pull out each SFP connector.
Figure 2. Fibre-channel SFP connector
- Slide the adapter straight back from the connector and
out of the riser-card assembly. Do not try to slide the adapter at
an angle.