Removing the SAN Volume Controller 2145-8F4 or SAN Volume Controller 2145-8F2 adapter assemblies

The SAN Volume Controller 2145-8F2 contains two types of fibre-channel adapters that are functionally identical but not interchangeable. The SAN Volume Controller 2145-8F4 contains a single 4-Port adapter in PCI slot 2.

Figure 1 shows the rear view of the SAN Volume Controller 2145-8F2 with the two fibre-channel ports identified:
Figure 1. Rear view of the SAN Volume Controller 2145-8F2 with fibre-channel ports indicatedRear view of SAN Volume Controller 2145-8F2 with fibre-channel ports
  • Reference key one PCI slot 1 - contains a dual port fibre-channel host bus adapter (HBA) in a low profile
  • Reference key two PCI slot 2 - contains a dual port fibre-channel HBA at full height
Figure 2 shows the rear view of the SAN Volume Controller 2145-8F4 with the 4-port fibre-channel HBA identified:
Figure 2. Rear view of the SAN Volume Controller 2145-8F4Rear view of the SAN Volume Controller 2145-8F4 with fibre-channel ports
  • Reference key one PCI slot 2 - contains a 4-port fibre-channel HBA
Perform the following steps to remove a fibre-channel adapter assembly:
  1. Turn off the node while ensuring that its data is mirrored and synchronized. See MAP 5350: Powering off a SAN Volume Controller node for more information.
  2. Remove the node from the rack and place it on a flat, static-protective surface. See Removing the SAN Volume Controller from a rack.
  3. Remove the top cover. See Removing the top cover.
  4. Perform the following steps to remove the PCI card from PCI slot 1 (low profile):
    1. Pull the blue PCI card retainer Reference key one from the rear of the node, shown in Figure 3.
      Figure 3. SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 PCI slot 1 card retainerShows the SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 PCI slot 1 card retainer
      • Reference key one Slot 1 card retainer
    2. Hold the blue adapter support away from the card and pull it away from the edge connector on the riser card assembly, as shown in Figure 4.
      Figure 4. SAN Volume Controller 2145-8F2 riser card and low profile adapterSAN Volume Controller 2145-8F2 overhead view
      • Reference key one Riser card
      • Reference key two Low-profile adapter
      • Reference key three Low-profile adapter support
  5. Perform the following steps to remove the PCI card from PCI slot 2:
    1. Open the retaining clips on both sides of the slot 2 riser card (Reference key two in Figure 5) by pushing the clips down and away from the riser card until the clips are no longer attached to the riser card.
      Note: Insert your finger into the access hole on the slot 2 adapter cover to open the retention latch at the rear of the node.
      Figure 5. SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 slot 2 adapterThis figure shows the SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 slot 2 adapter
      • Reference key one Access hole to retention latch
      • Reference key two Riser card
      • Reference key three Riser-card retention latches
    2. Unlatch the PCI slot 2 riser card Reference key two and pull it clear of the system-board edge connector.
    3. Lift the riser card clear of the frame and pull the fibre-channel card from the riser-card edge connector.
Library | Support | Terms of use | Feedback
© Copyright IBM Corporation 2003, 2009. All Rights Reserved.