Take
precautions to avoid damage from static electricity. Wear an anti-static
wrist strap and use a static-protected mat or surface. For more information,
see Handling static-sensitive devices.
Perform the following steps to remove a failed fan:
- Turn off the node while
ensuring that its data is mirrored and synchronized. See MAP 5350: Powering off a SAN Volume Controller node for
more information.
- Slide the node forward to gain access to the fan doors (
in Figure 1).
- Open the fan door for the failing fan. The LED near the
connector of the failing fan assembly is lit, unless you remove the
power cable.
Note: The node has six fan positions that
are numbered left to right under the two fan doors.
Figure 1. SAN Volume Controller 2145-8G4 fan
doors, locations, and connectors
- Disconnect the cable of the failing fan from the connector
on the system board by pressing the release latch on the plug at the
end of the cable.
- Pull up on the orange tab (
in Figure 1) of the failing
fan to lift the fan out of the node.