Removing a SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 power supply

Ensure that you are aware of the procedures for handling static-sensitive devices before you remove the SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 power supply.
Perform the following steps to remove the power supply:
  1. Turn off the node while ensuring that its data is mirrored and synchronized. See MAP 5350: Powering off a SAN Volume Controller node for more information.
  2. Turn off the 2145 UPS-1U that is supplying this node.
  3. Remove the SAN Volume Controller 2145-8F4 cable retention bracket.
  4. From the rear of the node, as shown in Figure 1, push the orange release lever to the left and then push down on it to release the power-supply assembly. This will move the power supply back, slightly, for easy removal.
    Figure 1. Removing the SAN Volume Controller 2145-8F2 power supply2145-8F2 with power supply removed
    • reference key one Handle
    • reference key two Power supply
    • reference key three dc power LED
    • reference key four ac power LED
  5. Pull the power supply out of the power-supply bay.
Library | Support | Terms of use | Feedback