Removing and replacing the 2145 UPS-1U power cable-retention bracket

The 2145 UPS-1U power cable-retention bracket prevents accidental removal of the power cable that connects the 2145 UPS-1U to the SAN Volume Controller node.

Note: The 2145 UPS-1U power cable-retention bracket (shown in Figure 1) can be attached only to the most recent versions of the 2145 UPS-1U. Older versions do not have the correct mounting holes.
Figure 1. 2145 UPS-1U power cable-retention bracket hardware
This figure shows the 2145 UPS-1U cable-retention bracket hardware

Removing the 2145 UPS-1U power cable-retention bracket

Perform the following steps to remove the 2145 UPS-1U power cable-retention bracket:

  1. Remove the retaining screw from each side of the bracket.
    Figure 2. 2145 UPS-1U power cable-retention bracket
    2145 UPS-1U power cable -retention bracket
  2. Lift the bracket off the cable.

Replacing the 2145 UPS-1U power cable-retention bracket

Perform the following steps to replace the 2145 UPS-1U power cable-retention bracket:

  1. Ensure that the output power cable is securely in place.
  2. Place the bracket over the power supply inlets on the right rear of the 2145 UPS-1U, so that the two screw holes line up.
  3. Ensure that the power cable runs through the rightmost slot in the bracket.
  4. Secure the bracket in place with one screw on each side, as shown in Figure 3.
    Figure 3. 2145 UPS-1U power cable-retention bracket
    2145 UPS-1U power cable -retention bracket