Follow these instructions when you are prompted to replace
the SAN
Volume Controller 2145-4F2 in
a rack.
Attention: Do
not touch the power control switches on adjacent SAN Volume Controller nodes
when you remove or install SAN Volume Controller nodes
in a rack. Touching these switches on adjacent SAN Volume Controller nodes
might cause those devices to turn off and make customer data inaccessible.
Perform the following steps to replace the SAN
Volume Controller 2145-4F2 in
the rack:
- Slide the SAN
Volume Controller 2145-4F2 node
into the rack.
- Screw in the two front screws ( 1 in Figure 1).
Note: The front of the rail assembly looks different
from the front, as you can see in
Figure 1.
Figure 1. Attaching the SAN
Volume Controller 2145-4F2 with
the front screws
- Reconnect the fibre-channel
and Ethernet cables. Ensure that you replace the fibre-channel
and Ethernet cables in the same ports from which they were removed.
- Reconnect the power cable.
- Turn on the node.