Replacing the SAN Volume Controller 2145-4F2 in a rack

Follow these instructions when you are prompted to replace the SAN Volume Controller 2145-4F2 in a rack.

Attention: Do not touch the power control switches on adjacent SAN Volume Controller nodes when you remove or install SAN Volume Controller nodes in a rack. Touching these switches on adjacent SAN Volume Controller nodes might cause those devices to turn off and make customer data inaccessible.

Perform the following steps to replace the SAN Volume Controller 2145-4F2 in the rack:

  1. Slide the SAN Volume Controller 2145-4F2 node into the rack.
  2. Screw in the two front screws ( 1  in Figure 1).
    Note: The front of the rail assembly looks different from the front, as you can see in Figure 1.
    Figure 1. Attaching the SAN Volume Controller 2145-4F2 with the front screws
    Attaching the SAN Volume Controller 2145-4F2 to the rack with the front screws
  3. Reconnect the fibre-channel and Ethernet cables. Ensure that you replace the fibre-channel and Ethernet cables in the same ports from which they were removed.
  4. Reconnect the power cable.
  5. Turn on the node.