Follow these instructions when you are prompted to replace
the SAN Volume Controller 2145-8G4.
Attention: Do
not touch the power control switches on adjacent SAN Volume Controller nodes
when you remove or install SAN Volume Controller nodes
in a rack. Touching these switches on adjacent SAN Volume Controller nodes
might cause those devices to turn off and make customer data inaccessible.
Perform the following steps to replace the SAN Volume Controller 2145-8G4 in
a rack:
- Fully extend the support slides.
- Align the node on the slide rails and push the node fully
into the rack. Secure the node to the front mounting flanges with
the captive thumbscrews ( 1 in Figure 1).
Figure 1. The captive thumbscrews
that secure the node and the shipping brackets
- Align the two rear wheels on the node with the opening
in the slides and then push the node into the slides until the rear
slide release latches ( 2 in Figure 2) click into place,
locking the node in the slides.
Figure 2. Aligning the SAN Volume Controller 2145-8G4 with
the rack slides
- Reconnect the fibre-channel
and Ethernet cables. Ensure that you replace the fibre-channel
and Ethernet cables in the same ports from which they were removed.
- Connect the power cable to the node and replace the
cable-retention bracket. See Replacing the cable-retention bracket.
- Turn on the node.