Take
precautions to avoid damage from static electricity. Wear an anti-static
wrist strap and use a static-protected mat or surface. For more information,
see Handling static-sensitive devices. The
replacement procedures in this topic assume that the following are
true:
- The failed fan is removed
- The node power is turned off
- The node is removed from the rack
Perform the following steps to replace the SAN Volume Controller 2145-8F4 or SAN Volume Controller 2145-8F2 fans:
- Orient the new fan in the same position as the fan you
removed. Make sure that the airflow indicator, on top of the fan,
is pointing to the rear of the server.
- Push the fan assembly down into the server until the blue
grommets are correctly seated.
- Connect the cable of the replacement fan into the connector.
- Close the fan door.
- Replace
the top cover. See Replacing the top cover.
- Place the node in the
rack. See Replacing the SAN Volume Controller in a rack.
- Reconnect the cables and power cords that were removed.
- Turn on the node.