This topic describes how to replace the SAN Volume Controller 2145-8G4 fans.
Take
precautions to avoid damage from static electricity. Wear an anti-static
wrist strap and use a static-protected mat or surface. For more information,
see Handling static-sensitive devices. The
replacement procedures in this topic assume that the following are
true:
- The failed fan is removed
- The node power is turned off
- The node is removed from the rack
Perform the following steps to replace a failed fan:
- Orient the new fan in the same position as the fan that
you removed. Make sure that the airflow indicator on the orange tab, (
in Figure 1) is pointing
to the rear of the node. Figure 1. SAN Volume Controller 2145-8G4 fan
doors, locations, and connectors
- Push the fan assembly down into the server until the blue
mounting grommets are correctly seated.
- Connect the cable of the replacement fan into the system
board connector.
- Close the fan door
.
- Place the node in the
rack. See Replacing the SAN Volume Controller in a rack.
- Turn on the node.