Replacing the SAN Volume Controller 2145-8G4 fans

This topic describes how to replace the SAN Volume Controller 2145-8G4 fans.

Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a static-protected mat or surface. For more information, see Handling static-sensitive devices. The replacement procedures in this topic assume that the following are true:
Perform the following steps to replace a failed fan:
  1. Orient the new fan in the same position as the fan that you removed. Make sure that the airflow indicator on the orange tab, (reference key two in Figure 1) is pointing to the rear of the node.
    Figure 1. SAN Volume Controller 2145-8G4 fan doors, locations, and connectorsThis figure shows the SAN Volume Controller 2145-8G4 with open fan doors showing fan locations and connectors
  2. Push the fan assembly down into the server until the blue mounting grommets are correctly seated.
  3. Connect the cable of the replacement fan into the system board connector.
  4. Close the fan door reference key one.
  5. Place the node in the rack. See Replacing the SAN Volume Controller in a rack.
  6. Turn on the node.