Perform the following steps to install the fibre-channel
card into the riser-card assembly:
Note: The adapter assemblies are electrostatic-discharge
sensitive.
Take
precautions to avoid damage from static electricity. Wear an anti-static
wrist strap and use a static-protected mat or surface. For more information,
see Handling static-sensitive devices.
- Install the fibre-channel card in slot 1, which is shown
in Figure 1.
Figure 1. SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 PCI
slot 1 card retainer
- Slide the I/O connector portion of the adapter through
the slot 1 opening and align the edge connector on the low-profile
adapter with the connector on the riser card. Press the edge connector
firmly into the riser-card connector. Make sure that the adapter snaps
into the riser card securely and the adapter is lying on top of the
low-profile adapter support.
- Push the adapter down past the tab so that the adapter
snaps into place on the support.
- Check the retention latches on the riser card and make
sure that they are still securely in place.
- Close the fibre-channel card retainer to secure the
card.
- Install the fibre-channel card in slot 2.
- Align the edge connector on the fibre-channel adapter
with the connector on the riser card. Press the edge connector firmly
into the riser-card connector. The card is fully installed when the
gold connectors on the edge of the fibre-channel cards are no longer
visible.
- Grasp the riser card assembly by its top edge or upper
corners and align the riser card with the guides for the riser-card
connector.
- Press the riser card edge connector firmly into the
slot 2 riser-card edge connector on the system board. Make sure that
the retention latches snap into place to secure the riser card into
the slot 2 riser-card connector.
- Replace
the top cover. See Replacing the top cover.
- Place the node in the
rack. See Replacing the SAN Volume Controller in a rack.