Replacing the SAN Volume Controller 2145-8G4 power backplane

This topic describes how to replace the SAN Volume Controller 2145-8G4 power backplane.

Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a static-protected mat or surface. For more information, see Handling static-sensitive devices.
Perform the following steps to replace the power backplane:
  1. Align the keyhole slots in the power-supply backplane with the mounting pins in the node.
  2. Slide the power-supply backplane toward the right side of the node until the edge-connectors are fully connected.
  3. Reconnect the cables to the power-supply backplane.
  4. Install the power supply into the power-supply bay as shown in Figure 1.
    Figure 1. SAN Volume Controller 2145-8G4 power backplaneSAN Volume Controller 2145-8G4 power backplane
  5. Replace the top cover. See Replacing the top cover.
  6. Place the node in the rack. See Replacing the SAN Volume Controller in a rack.
  7. Reconnect the fibre-channel and Ethernet cables. Ensure that you replace the fibre-channel and Ethernet cables in the same ports from which they were removed.
  8. Turn on the node.