Replacing the SAN Volume Controller 2145-CF8 SAS boot drive

You can replace the serial attached SCSI (SAS) boot drive for the SAN Volume Controller 2145-CF8 node.

DANGER
Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords.

The following notes describe information that you must consider when you install a hard-disk drive.

To replace a SAN Volume Controller 2145-CF8 disk drive, perform the following steps:

  1. Read the safety information to which Preparing to remove and replace parts refers.
  2. Make sure that the node cover is in place and fully closed.
    Attention: To avoid damage to the disk-drive connectors, make sure that the node cover is in place and fully closed whenever you remove or replace a disk drive.
  3. Touch the static-protective package that contains the drive to any unpainted metal surface on the node; then, remove the drive from the package and place it on a static-protective surface.
  4. Make sure that the disk-drive handle is in the open (unlocked) position.
    Figure 1. Drive-bay filler panel and disk-drive handle for the SAN Volume Controller 2145-CF8
    Drive-bay filler panel and disk-drive handle for the SAN Volume Controller 2145-CF8
    •  1  Drive bay filler panel (used in all empty drive bays)
    •  2  SAS disk drive with handle extended
  5. Align the drive assembly with the guide rails in drive bay 4, which is the top bay on the right of the node when viewed from the front.
  6. Gently push the drive assembly into the bay until the drive stops.
  7. Rotate the tray handle to the closed (locked) position.
  8. Install the service controller. See Replacing the service controller.
  9. If you removed the node from the rack, replace the node in the rack, as described in Replacing the SAN Volume Controller in a rack.
  10. Make sure that all cables, adapters, and other components are installed and seated correctly and that you have not left loose tools or parts inside the node. Make sure that all internal cables are correctly routed. If you disconnected the fibre-channel and Ethernet cables, make sure that each cable is reconnected to the same port from which it was removed.
  11. If you removed the power cords, replace the power cords and the cable-retention brackets, as described in Replacing the cable-retention bracket.
  12. Lift the locking levers ( 1  in Figure 2) on the slide rails and push the server  2  all the way into the rack until it clicks into place.
    Figure 2. Raising the SAN Volume Controller 2145-CF8 locking levers of the slide rails of the rack
    Raising the SAN Volume Controller 2145-CF8 locking levers of the slide rails of the rack
  13. Turn on the node. When you turn on the node, use the node rescue procedure to install the SAN Volume Controller software on the new disk. Then add the node back into the cluster. See Performing the node rescue.
    Note: If you must replace the hard disk and the service controller at the same time, you might not be able to start the node to perform node rescue. See Replacing a disk drive and a service controller on the SAN Volume Controller.