Replacing the SAN Volume Controller 2145-4F2 power supply

Note: For a translation of the following notice, see IBM® Systems Safety Notices.
DANGER
Do not open or service any power supply assembly. (D005a)

Perform the following steps to replace the SAN Volume Controller 2145-4F2 power supply:

  1. Slide the power supply  4  into the SAN Volume Controller 2145-4F2 node, as shown in Figure 1.
    Figure 1. Replacing the SAN Volume Controller 2145-4F2 power supply
    Removing the SAN Volume Controller 2145-4F2 power supply
  2. Replace the screw  3 .
  3. Connect the power connector  2 .
  4. Place the power-cable module into the node.
  5. Slide the module toward the back of the node until the alignment tab snaps into the slot that is on the side of the SAN Volume Controller 2145-4F2.
  6. Replace the disk drive fan.
  7. Replace the top cover. See Replacing the top cover.
  8. Place the node in the rack. See Replacing the SAN Volume Controller in a rack.
  9. Turn on the node.