Replacing the
SAN Volume Controller 2145-4F2
power supply
Note:
For a translation of the following notice, see
IBM® Systems Safety Notices
.
DANGER
Do not open or service any power supply assembly. (D005a)
Perform the following steps to replace the
SAN Volume Controller 2145-4F2
power supply:
Slide the power supply
4
into the
SAN Volume Controller 2145-4F2
node, as shown in
Figure 1
.
Figure 1. Replacing the
SAN Volume Controller 2145-4F2
power supply
Replace the screw
3
.
Connect the power connector
2
.
Place the power-cable module into the node.
Slide the module toward the back of the node until the alignment tab snaps into the slot that is on the side of the
SAN Volume Controller 2145-4F2
.
Replace the disk drive fan.
Replace the top cover
.
See
Replacing the top cover
.
Place
the node in the rack.
See
Replacing the SAN Volume Controller in a rack
.
Turn on the node.
Parent topic:
Replacing the power supply