Replacing the SAN Volume Controller 2145-8F4 or SAN Volume Controller 2145-8F2 power supply

Ensure that you are aware of the procedures for handling static-sensitive devices before you remove the power supply.
To replace the SAN Volume Controller 2145-8F4 or SAN Volume Controller 2145-8F2 power supply, perform the following steps:
  1. Install the power supply in the empty power supply bay:
    1. Rotate the handle reference key one down on the rear of the power supply to the open position, and then slide the power supply forward into the power-supply bay, as shown in Figure 1.
      Figure 1. SAN Volume Controller 2145-8F2 power supplyThis figure shows the SAN Volume Controller 2145-8F2 power supply
      • reference key one Handle
      • reference key two Power supply
      • reference key three Dc power LED
      • reference key four Ac power LED
    2. Gently lift the handle up until it clicks. This signals that the power supply is securely seated in the bay.
  2. Connect the power cord for the new power supply to the power-cord connector on the power supply.
  3. Reconnect the power cord and turn on the 2145 UPS-1U.
  4. Turn on the node.
  5. Make sure that the power-supply fan starts and the ac power LED reference key one and dc power LED reference key two (shown in Figure 2) on the power supply are lit, indicating that the power supply is operating correctly.
    Figure 2. SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 ac and dc power LEDsThis figure shows the SAN Volume Controller 2145-8F2 or SAN Volume Controller 2145-8F4 ac and dc power LEDs